Configuring Control-M Workload Change Manager E-mail Notifications

This procedure describes how to enable Control-M Workload Change Manager to send e-mail notifications from the administrator.

To configure Control-M Workload Change Automation E-mail Notifications:

  1. From CCM, from the Home tab, click System Parameters.

    The Control-M-EM - System Parameters window opens.

  2. In the left pane, click the Advanced tab, navigate to the general type parameters and click the EmailServer parameter.
  3. In the Value field, enter a valid email server and click Save.
  4. In the left pane, click the Workload Change Manager tab, enter the administrator e-mail address in the E-mail Sender field, click Activate Changes and Close.
  5. Set the Desired State of CMS to Recycle.

Parent Topic

Control-M/EM system parameters